I Can’t Imagine Life Without It

I Can’t Imagine Life Without It

 

Whereas the MiniMed 670G system has been obtainable for the previous two years, we obtain loads of questions on the expertise these utilizing the system have had. Immediately, I’d wish to introduce you to Nalani, a doctor assistant in California who dedicates her life to serving to others with diabetes. Nalani has been dwelling with sort 1 diabetes since she was Eight years outdated and began her first insulin pump at 10 years outdated. She began on the MiniMed 670G system two years in the past and immediately talks about how the system has impacted her life.

I’ve just lately been fascinated by how a lot I like my MiniMed 670G system. Once I say that I find it irresistible, I imply that I can’t think about my life with out it.

I’ve all the time had superb management. Earlier than beginning the MiniMed 670G system my A1c degree was 5.8%. I had fairly regular blood sugars (BGs) and appreciated to run them between 70-100mg/dL as typically as I might. I’ve all the time been extra afraid of the highs than the lows as a result of I fear about issues, however as a result of I used to be operating my glucose so tight, I used to be experiencing a major low at the very least a couple of times per week. I stay an lively life-style, have an extremely demanding job, and the battle to maintain my BGs low, however not too low was tough.

Once I first began the MiniMed 670G system I used to be pissed off as a result of my glucose was all the time within the mid 100’s, which was WAY too excessive for my consolation. There have been many instances that I wished to cease utilizing SmartGuard Auto Mode in order that I might have my 80’s and 90’s again. As a substitute, I made a decision to stay it out, and I’m so glad that I did.

After Three months I retested my A1c and it was 6.4%. I used to be thrilled! Not solely was my A1c nonetheless at purpose, however I used to be not having any* lows. I’ve been on the MiniMed 670G system now for over 2 years and that 6.4% was the very best A1c that I’ve had. Not solely that, however my lows are basically gone, and my glucose is far more secure.

I initially struggled with alarm fatigue as a result of frequent BG/calibration alarms, however being in Auto Mode was value it. Fortunately, Medtronic now has an enhanced Guardian Hyperlink transmitter and most, if not all, of my pointless alarms have been eradicated!

The MiniMed 670G system has given me loads of issues again. I’ve had diabetes for mainly my entire life and didn’t even understand how regularly I used to be fascinated by my glucose, making small pump changes, or consuming little snacks to try to keep away from my hypos (I’m a micromanaging diabetic). Beginning on the system was the primary time since I can do not forget that I’ve been capable of sleep by the evening. I can now train, clear my home, and go dust biking with out concern of low BGs.

I can’t consider how fortunate I’m to put on this wonderful product. Now, let me inform you a bit concerning the technical facet.

Auto Mode makes use of a particular algorithm to constantly modify the quantity of insulin given by the pump. This small spurt of insulin, which is recalculated by the algorithm each 5 minutes, relies on the person’s sensor readings, and augments the pump’s basal characteristic whereas in Auto Mode. This algorithm targets a sensor glucose of 120mg/dL (may be adjusted to 150mg/dL throughout train) and readjusts its settings each evening at midnight primarily based on the earlier 6 days of information.

You will need to do not forget that as with different pumps, the person nonetheless must enter their carbs into the bolus calculator. Auto Mode makes use of the identical carb setting for the bolus calculator in Auto Mode because it does in Handbook Mode. You and your clinician might want to work collectively to give you your applicable carb issue. Correction boluses are calculated by the algorithm and goal the correction to a sensor glucose of 150mg/dL. The algorithm then continues to make use of the micro-bolus characteristic to appropriate the glucose to the 120mg/dL goal.

Most of the sufferers I’ve seen in Auto Mode spend <1% of time in hypoglycemia!

As I discussed earlier, the MiniMed 670G system has accomplished wonders for me. It was an adjustment interval and it took me some time to let go of management, however general my expertise with this pump has been wonderful and I’m really grateful.

 

*Particular person Outcomes Might Range

 

Necessary Security Info

The Medtronic MiniMed™ 670G system is meant for steady supply of basal insulin (at person selectable charges) and administration of insulin boluses (in person selectable quantities) for the administration of sort 1 diabetes mellitus in individuals, seven years of age and older, requiring insulin in addition to for the continual monitoring and trending of glucose ranges within the fluid underneath the pores and skin. The MiniMed™ 670G system contains SmartGuard™ know-how, which may be programmed to mechanically alter the supply of basal insulin primarily based on Steady Glucose Monitor sensor glucose values,and may droop supply of insulin when the sensor glucose worth falls under or is predicted to fall under predefined threshold values. The system requires a prescription. The Guardian™ Sensor (3) glucose values are usually not supposed for use immediately for making remedy changes, however slightly to supply a sign of when a fingerstick could also be required.

A confirmatory finger stick take a look at by way of the CONTOUR®NEXT LINK 2.Four blood glucose meter is required prior to creating changes to diabetes remedy. All remedy changes must be primarily based on measurements obtained utilizing the CONTOUR®NEXT LINK 2.Four blood glucose meter and never on values offered by the Guardian Sensor (3).  All the time test the pump show to make sure the glucose end result proven agrees with the glucose outcomes proven on the CONTOUR®NEXT LINK 2.Four blood glucose meter. Don’t calibrate your CGM system or calculate a bolus utilizing a blood glucose meter end result taken from an Various Website (palm) or from a management answer take a look at. It is usually not really useful to calibrate your CGM system when sensor or blood glucose values are altering quickly, e.g., following a meal or bodily train.  If a management answer take a look at is out of vary, please notice that the end result could also be transmitted to your pump when within the “All the time” ship mode.

Pump remedy just isn’t really useful for folks whose imaginative and prescient or listening to doesn’t permit recognition of pump alerts and alarms. Pump remedy just isn’t really useful for people who find themselves unwilling or unable to keep up contact with their healthcare skilled. The security of the MiniMed™ 670G system has not been studied in pregnant ladies. For full particulars of the system, together with product and necessary security data comparable to indications, contraindications, warnings, and precautions related to system and its parts, please seek the advice of http://www.medtronicdiabetes.com/important-safety-information#minimed-670g and the suitable person information at http://www.medtronicdiabetes.com/download-library

The put up I Can’t Think about Life With out It appeared first on The LOOP Weblog.

Leave a Comment

Your email address will not be published. Required fields are marked *